Fleximmer. The dimmer for data centre power.

Technology

FlexOptim models the whole data centre as one system.

A data centre’s flexibility doesn’t sit in any one system. It comes from how IT workload, power and cooling work together. FlexOptim models them together.

The problem

Flexibility is easy to find. It is hard to promise.

A data centre has four main sources of flexibility. Each one gives something, and each one has a limit.

IT workload

Gives
Some work can move in time or place.
Limit
Much of it is bound by customer SLAs.

UPS and batteries

Gives
They carry load for a while.
Limit
Each kilowatt-hour used for the grid is backup the site no longer holds in reserve.

Cooling and thermal mass

Gives
A site can pre-cool, or ride through a short reduction.
Limit
Temperatures stay inside limits, and the site needs time to recover.

On-site generation

Gives
Power from the site’s own permitted resources.
Limit
Bound by permits, fuel and operating rules.

They don’t add up. They interact.

So what a site can safely give back is not a fixed number. It changes with:

  • Time of day and season
  • How long
  • How often
  • How fast it must recover
Installed is not the same as availableIllustrative
Installed capability What the site can safely give back Start of dayEnd of day
Sum of the nameplate ratingsInside every limit, hour by hour

Our approach

One coupled model, inside every limit.

Fleximmer treats the data centre as one coupled system. It does not add up separate estimates for each asset.

Grid connectionFirm and non-firm capacity
One data centre
IT workload
UPS / batteries
Cooling & thermal
On-site resources
FlexOptim

Modelled together, as one coupled system

  • Limits
  • SLAs
  • Reserves
  • Temperatures
  • Permits
  • Control rights
  • Recovery

Once, at the connection decision

The flexibility envelope

What the site can give back: how much, how fast, for how long, how often, and what limits it.

Every day, in operation

The operating plan Next

A daily plan for IT workload and energy assets that keeps the commitment. The site’s operator approves it.

The engine

FlexOptim is Fleximmer’s optimisation engine.

  1. Represents

    IT workload, UPS/batteries, cooling and thermal behaviour, and other permitted on-site resources, as one coupled system.

  2. Respects

    Every limit the operator sets: customer SLAs, backup reserves, temperature limits, permits, control rights and recovery time.

  3. Calculates

    The site’s flexibility envelope: how much the site can reduce, for how long, at what times, how often, and how fast it recovers.

  4. Produces

    The operating plan that keeps a commitment once it is made. That is the Operate stage. Next

The first application First application

A flexibility commitment your data centre can keep.

Fleximmer’s Flexibility Commitment is made for the moment a data centre negotiates its grid connection. For a defined connection constraint, it shows:

  • How much the site can reduce its grid import, and for how long.
  • When it can do so, by hour and by season.
  • How often, and how quickly it recovers.
  • Which resources carry the load, and which limits bind first.

It is evidence that a developer, an operator and a network operator can discuss on the same terms.

Why grid connections are changing

One engine, three stages

Commit. Operate. Scale.

Commit First application

The Flexibility Commitment: what the site can safely commit, before the connection decision.

Operate Next

A daily operating plan that keeps the commitment within every limit.

Scale Later

Operator-approved automation, energy savings, grid services and multi-site portfolios.

Reliability

Reliability comes first.

Five rules sit behind everything we model.

  1. Customer commitments come first.SLAs are hard limits, not costs to trade off.
  2. Resilience is preserved.Backup reserves stay inside the limits the operator sets.
  3. Every limit is explicit.Temperatures, permits, equipment ratings and operating rules are modelled as constraints.
  4. Recovery is part of the answer.A reduction only counts if the site can recover in time for the next one.
  5. The operator decides.Fleximmer informs the operator’s decisions. Control rights stay with the site.

Talk to us about a site or a connection decision.